Canopy Steel Structure High Speed & Precision

The Wedospace adopts the national standard Q345B high-strength carbon steel and 85 micron hot-dip galvanized anti-corrosion process. This Canopy Steel Structure has a wind load resistance of 0.6 kN per square meter, providing all-weather protection with a service life of more than 50 years for large-scale construction projects and accepting large orders.

Canopy Steel Structure

gear

The Q345B grade structural steel with yield strength greater than 345 MPa is selected, which increases the strength by about 15% compared with ordinary Q235 steel, reduces the amount of steel under the same load and reduces the load-bearing burden of the foundation.

gear

After pickling, the components are hot-dip galvanized. The thickness of the zinc layer is strictly controlled above 85 microns. It has passed the ISO 1461 standard test and can be maintained for 50 years without rust in humid and coastal salt spray environments.

gear

All steel components are cut and drilled in the factory, and the tolerance of connecting holes is controlled within 1mm. Compared with the on-site welding construction, the on-site bolt assembly efficiency is improved by 40%, and the construction period is greatly shortened.

gear

After strict mechanical calculation, the structural design has a constant load design value of 0.3 kN per square meter and a live load of 0.5 kN per square meter, which can easily cope with the once-in-a-century blizzard backlog and typhoon attack.

gear

The embedded 304 stainless steel drainage gutter is adopted, and the cross-sectional size is accurately calculated according to the catchment area, so as to ensure smooth drainage under 50mm rainfall per hour and completely eliminate the overflow of canopy and water stains on the facade.

gear

The key connection nodes between the main beam and the column are welded by full penetration groove, and 100% ultrasonic flaw detection is carried out before leaving the factory to ensure that there are no pores and slag in the weld and ensure the safety and stability of the overall structure.

Parameter categoriesTechnical indicatorsNotes
Product NameCanopy Steel StructureCustomized engineering components
Steel column and main beam materialQ345B / Q235B low alloy high strength structural steelCompliant with GB/T 1591 standard
Purlin systemC-shaped or Z-shaped cold-formed thin-walled steel (Q235B)Surface hot-dip galvanizing amount 275g/㎡
Surface anti-corrosion treatmentHot-dip galvanizing (≥85μm) or epoxy zinc-rich primer (2 coats)Select according to the environmental corrosion level
Wind load design0.60 kN/㎡ – 1.2 kN/㎡It can withstand typhoons of level 12-14.
Snow load resistance design0.50 kN/㎡ – 1.0 kN/㎡Adapted to high-latitude snowfall areas
Seismic fortification intensity8 degreesGood structural ductility and excellent seismic performance
Covering material compatibilityTempered laminated glass, polycarbonate sheets, and color steel roofing sheetsAdaptable to various architectural aesthetic needs
Connection method10.9 grade high-strength bolt connectionNo open flame installation on site
Fire resistance ratingLevel 2 and aboveUltra-thin fire-retardant coating can be applied.
This Canopy Steel Structure is better than the conventional market standards in material selection and processing technology. Conventional products are mostly made of ordinary Q235 steel and the galvanized layer is often less than 60 microns, resulting in corrosion and yellow water phenomenon after 3 to 5 years. The Wedospace uses high-strength Q345B steel with heavy anti-corrosion process to ensure that the structure is maintenance-free in the whole life cycle. In addition, we introduced BIM modeling technology in the design stage to check the collision in advance to ensure zero error in on-site installation, and solved the problems of component dislocation and forced assembly that often occur in traditional canopy construction.
Canopy Steel Structure Comparison Point
solution

Eliminate the hidden danger of rust and fracture at the weld

In view of the problem that the weld seam of the traditional canopy is easy to break due to stress concentration and inadequate anti-corrosion, the Wedospace adopts the factory prefabricated automatic submerged arc welding process, the qualified rate of weld flaw detection is 100%, and the weld area is thickened and anti-corrosion treatment, so that the connection point strength is higher than the base metal.
solution

Solve the problem of gutter backflow in rainstorm weather

In view of the pain point that rainwater often flows back into the room due to poor drainage in the canopy of commercial buildings, the Wedospace optimizes the design of the gutter section, configures a large-diameter downpipe and adds an overflow port, so that even under the heavy rain of 100mm per hour, rainwater can be discharged smoothly without accumulating water and flowing back.
solution

Improve the defects of large cantilever structure sagging deformation

In view of the problem that the front end of the large-span cantilever canopy is obviously drooping after several years of use, the Wedospace accurately calculates the deflection value through the pre-arching design and finite element force analysis, and controls the vertical deformation of the cantilever end within 1/400 of the span.

Large commercial complex developers

Applicable to the main entrance canopy of shopping centers, star hotels and office buildings. This group focuses on architectural aesthetics and safety. Our steel structure scheme supports large span and column-free design, which can perfectly match the modern glass curtain wall facade and enhance the image of commercial real estate.

Canopy Steel Structure Applicable crowd

Industrial Logistics Park Builder

Suitable for unloading platform canopy in logistics storage center. This group requires extreme durability and headroom, and our high-strength structures can withstand frequent forklift vibrations and severe weather, ensuring uninterrupted logistics operations around the clock.

Canopy Steel Structure Applicable crowd

public transport infrastructure contractor

It is suitable for the connecting canopy of high-speed railway station, airport terminal and bus hub. This group is concerned about the safety factor in densely populated areas. Our structure has undergone strict wind-resistant and seismic calculations and meets the national first-class public building safety standards.

Canopy Steel Structure Applicable crowd

High-end residential community planner

It is suitable for the entrance and exit of the underground garage in the villa area and the canopy of the residential gate. This group pays attention to detail quality and mute effect. Our structure is matched with mute glass or noise reduction plate, which can effectively reduce raindrop impact noise and create a quiet living environment.

Canopy Steel Structure Applicable crowd
011

Before installing the steel column, be sure to use the total station to review the position of the embedded bolts on the concrete foundation. The center deviation shall be controlled within 2mm to ensure that the verticality of the Canopy Steel Structure column meets the specifications.

022

The 10.9 grade high-strength bolts connecting the main beam and the column must be tightened in two times. After initial tightening to 50% of the standard torque, the final tightening shall be carried out after adjusting the structure position. It is strictly prohibited to tighten once to prevent uneven stress distribution in the structure.

033

After the cover plate is installed, the joints shall be filled with weather resistant silicone sealant. The glue injection should be carried out in dry weather, and the width of the glue layer should not be less than 10mm to ensure that a continuous and complete waterproof layer is formed after curing.

044

It is recommended that the surface of the steel structure be visually inspected every 12 months. If the paint surface is damaged due to external force, it shall be polished and derusted immediately and coated with epoxy zinc-rich primer of the same brand to prevent the spread of rust.

certificate

factory

Welcome to our Frequently Asked Questions page. We have compiled answers to common questions you may have, hoping to provide you with clear and quick solutions. If you cannot find the information you need here, please feel free to contact our customer support team.

Q1: How much wind can this Canopy Steel Structure resist?
A: According to the design standard, our standard product design wind pressure is 0.6kN/㎡, which is equivalent to being able to withstand 12 typhoons. For coastal areas with high incidence of typhoons, we can customize the strengthening scheme, and the wind resistance level can be raised to above 14.
Q2: How long can the anti-corrosion and anti-rust of the steel structure canopy last?
A: We use a composite coating system of hot-dip galvanized or epoxy zinc-rich primer plus fluorocarbon topcoat. In the normal urban atmospheric environment, the anti-corrosion life can reach more than 50 years; in heavy industry or seaside environment, it can also maintain no obvious corrosion for more than 20 years.
Q3: Whether to support the cantilever design of large span without column?
A: Support. By using variable cross-section H-beam or tie rod auxiliary system, we can realize the cantilever length of 5 meters to 10 meters without column design, not only to ensure the safety of the structure, but also to provide an open ground space.
Q4: When the product is shipped, is it the whole machine or the parts?
A: Considering transportation costs and restrictions, Canopy Steel Structure uses prefabricated bulk shipments. All components are machined, drilled and painted in the factory, and only modular assembly by bolts is required on site, and no field welding is required.
Q5: Can the top of this steel structure canopy be laid with photovoltaic panels?
A: Yes. The Q345B steel structure has a very high bearing margin. If you plan to install a photovoltaic power generation system, please inform us at the design stage, we will include the constant load of the photovoltaic panel, and strengthen the purlin system to ensure safety.
Q6: Compared with aluminum alloy canopy, what are the advantages of steel structure canopy?
A: Compared with aluminum alloy, the biggest advantage of Canopy Steel Structure is high strength and low cost. For large span, high load (such as due to snow or maintenance load) application scenarios, the rigidity and deformation resistance of steel structure is much better than that of aluminum alloy, and the cost is reduced by about 30%.
E-mail*
Number
Country
Name
Your Question
Submitting!
Success!
Submission failed! Please try again later!
Email format error!
Format error!

Canopy Steel Structure High Speed & Precision

The Wedospace adopts the national standard Q345B high-strength carbon steel and 85 micron hot-dip galvanized anti-corrosion process. This Canopy Steel Structure has a wind load resistance of 0.6 kN per square meter, providing all-weather protection with a service life of more than 50 years for large-scale construction projects and accepting large orders.

Canopy Steel Structure

gear

The Q345B grade structural steel with yield strength greater than 345 MPa is selected, which increases the strength by about 15% compared with ordinary Q235 steel, reduces the amount of steel under the same load and reduces the load-bearing burden of the foundation.

gear

After pickling, the components are hot-dip galvanized. The thickness of the zinc layer is strictly controlled above 85 microns. It has passed the ISO 1461 standard test and can be maintained for 50 years without rust in humid and coastal salt spray environments.

gear

All steel components are cut and drilled in the factory, and the tolerance of connecting holes is controlled within 1mm. Compared with the on-site welding construction, the on-site bolt assembly efficiency is improved by 40%, and the construction period is greatly shortened.

gear

After strict mechanical calculation, the structural design has a constant load design value of 0.3 kN per square meter and a live load of 0.5 kN per square meter, which can easily cope with the once-in-a-century blizzard backlog and typhoon attack.

gear

The embedded 304 stainless steel drainage gutter is adopted, and the cross-sectional size is accurately calculated according to the catchment area, so as to ensure smooth drainage under 50mm rainfall per hour and completely eliminate the overflow of canopy and water stains on the facade.

gear

The key connection nodes between the main beam and the column are welded by full penetration groove, and 100% ultrasonic flaw detection is carried out before leaving the factory to ensure that there are no pores and slag in the weld and ensure the safety and stability of the overall structure.

Parameter categoriesTechnical indicatorsNotes
Product NameCanopy Steel StructureCustomized engineering components
Steel column and main beam materialQ345B / Q235B low alloy high strength structural steelCompliant with GB/T 1591 standard
Purlin systemC-shaped or Z-shaped cold-formed thin-walled steel (Q235B)Surface hot-dip galvanizing amount 275g/㎡
Surface anti-corrosion treatmentHot-dip galvanizing (≥85μm) or epoxy zinc-rich primer (2 coats)Select according to the environmental corrosion level
Wind load design0.60 kN/㎡ – 1.2 kN/㎡It can withstand typhoons of level 12-14.
Snow load resistance design0.50 kN/㎡ – 1.0 kN/㎡Adapted to high-latitude snowfall areas
Seismic fortification intensity8 degreesGood structural ductility and excellent seismic performance
Covering material compatibilityTempered laminated glass, polycarbonate sheets, and color steel roofing sheetsAdaptable to various architectural aesthetic needs
Connection method10.9 grade high-strength bolt connectionNo open flame installation on site
Fire resistance ratingLevel 2 and aboveUltra-thin fire-retardant coating can be applied.

Canopy Steel Structure Comparison Point

Canopy Steel Structure Comparison Point
solution
Eliminate the hidden danger of rust and fracture at the weld
In view of the problem that the weld seam of the traditional canopy is easy to break due to stress concentration and inadequate anti-corrosion, the Wedospace adopts the factory prefabricated automatic submerged arc welding process, the qualified rate of weld flaw detection is 100%, and the weld area is thickened and anti-corrosion treatment, so that the connection point strength is higher than the base metal.
solution
Solve the problem of gutter backflow in rainstorm weather
In view of the pain point that rainwater often flows back into the room due to poor drainage in the canopy of commercial buildings, the Wedospace optimizes the design of the gutter section, configures a large-diameter downpipe and adds an overflow port, so that even under the heavy rain of 100mm per hour, rainwater can be discharged smoothly without accumulating water and flowing back.
solution
Improve the defects of large cantilever structure sagging deformation
In view of the problem that the front end of the large-span cantilever canopy is obviously drooping after several years of use, the Wedospace accurately calculates the deflection value through the pre-arching design and finite element force analysis, and controls the vertical deformation of the cantilever end within 1/400 of the span.

Large commercial complex developers

Applicable to the main entrance canopy of shopping centers, star hotels and office buildings. This group focuses on architectural aesthetics and safety. Our steel structure scheme supports large span and column-free design, which can perfectly match the modern glass curtain wall facade and enhance the image of commercial real estate.

Canopy Steel Structure Applicable crowd

Industrial Logistics Park Builder

Suitable for unloading platform canopy in logistics storage center. This group requires extreme durability and headroom, and our high-strength structures can withstand frequent forklift vibrations and severe weather, ensuring uninterrupted logistics operations around the clock.

Canopy Steel Structure Applicable crowd

public transport infrastructure contractor

It is suitable for the connecting canopy of high-speed railway station, airport terminal and bus hub. This group is concerned about the safety factor in densely populated areas. Our structure has undergone strict wind-resistant and seismic calculations and meets the national first-class public building safety standards.

Canopy Steel Structure Applicable crowd

High-end residential community planner

It is suitable for the entrance and exit of the underground garage in the villa area and the canopy of the residential gate. This group pays attention to detail quality and mute effect. Our structure is matched with mute glass or noise reduction plate, which can effectively reduce raindrop impact noise and create a quiet living environment.

Canopy Steel Structure Applicable crowd
011

Before installing the steel column, be sure to use the total station to review the position of the embedded bolts on the concrete foundation. The center deviation shall be controlled within 2mm to ensure that the verticality of the Canopy Steel Structure column meets the specifications.

022

The 10.9 grade high-strength bolts connecting the main beam and the column must be tightened in two times. After initial tightening to 50% of the standard torque, the final tightening shall be carried out after adjusting the structure position. It is strictly prohibited to tighten once to prevent uneven stress distribution in the structure.

033

After the cover plate is installed, the joints shall be filled with weather resistant silicone sealant. The glue injection should be carried out in dry weather, and the width of the glue layer should not be less than 10mm to ensure that a continuous and complete waterproof layer is formed after curing.

044

It is recommended that the surface of the steel structure be visually inspected every 12 months. If the paint surface is damaged due to external force, it shall be polished and derusted immediately and coated with epoxy zinc-rich primer of the same brand to prevent the spread of rust.

Know Us and Contact Us

*
Submitting!
Success!
Submission failed! Please try again later!
Email format error!
Format error!
FAQ

FAQ

Q1: How much wind can this Canopy Steel Structure resist?
A: According to the design standard, our standard product design wind pressure is 0.6kN/㎡, which is equivalent to being able to withstand 12 typhoons. For coastal areas with high incidence of typhoons, we can customize the strengthening scheme, and the wind resistance level can be raised to above 14.
Q2: How long can the anti-corrosion and anti-rust of the steel structure canopy last?
A: We use a composite coating system of hot-dip galvanized or epoxy zinc-rich primer plus fluorocarbon topcoat. In the normal urban atmospheric environment, the anti-corrosion life can reach more than 50 years; in heavy industry or seaside environment, it can also maintain no obvious corrosion for more than 20 years.
Q3: Whether to support the cantilever design of large span without column?
A: Support. By using variable cross-section H-beam or tie rod auxiliary system, we can realize the cantilever length of 5 meters to 10 meters without column design, not only to ensure the safety of the structure, but also to provide an open ground space.
Q4: When the product is shipped, is it the whole machine or the parts?
A: Considering transportation costs and restrictions, Canopy Steel Structure uses prefabricated bulk shipments. All components are machined, drilled and painted in the factory, and only modular assembly by bolts is required on site, and no field welding is required.
Q5: Can the top of this steel structure canopy be laid with photovoltaic panels?
A: Yes. The Q345B steel structure has a very high bearing margin. If you plan to install a photovoltaic power generation system, please inform us at the design stage, we will include the constant load of the photovoltaic panel, and strengthen the purlin system to ensure safety.
Q6: Compared with aluminum alloy canopy, what are the advantages of steel structure canopy?
A: Compared with aluminum alloy, the biggest advantage of Canopy Steel Structure is high strength and low cost. For large span, high load (such as due to snow or maintenance load) application scenarios, the rigidity and deformation resistance of steel structure is much better than that of aluminum alloy, and the cost is reduced by about 30%.
certificate